pH Setup
Dose Type | Acid |
Set Point | 7.35 |
Proportional Band | 0.4 pH |
pH Flow Rate | 1.0 L/h |
Overtime | 60 min |
Alarm High | 8.5 pH |
Alarm High | Enabled |
Alarm Low | 6.5 pH |
Alarm Low | Enabled |
Warnings and Errors | Enabled |
Startup Dosing Delay. | 4 min |
Analog Out | A01 |
Max Analog Out | 12pH |
Min Analog Out | 2 pH |
Acid Tank Input | Disabled |
ORP Setup
Set Point | 735mv |
Proportional Band | 70mv |
Cl2 Flow Rate | 1.0 L/h |
Overtime | 60 min |
Alarm High | 950mv |
Alarm High | Enabled |
Alarm Low | 350mv |
Alarm Low | Enabled |
Warnings and Errors | Enabled |
Alarm Activates Relay | Enabled |
Startup Dosing Delay | 4 min |
Analog Out | A02 |
Analog Max | 2000mv |
Analog Min | 0mv |
Cl2 Tank Input | Disabled |
Temp Settings
Alarm High | 110 |
Alarm High | Enabled |
Alarm Low | 35 |
Alarm Low | Enabled |
Warnings and Errors | Enabled |
Alarm Activates relay | Enabled |
Unit | Fahrenheit |
Analog Out | A03 |
Analog Max | 221.0 F |
Analog Min | 23.0F |
General Settings
Date/Time | -Set at Plunge- |
Unit ID | -Set at Plunge- |
Key Beep | Enabled |
Hold Input | Enabled |