Use these Commercial preparation and restart steps with the common deep-clean procedure. Read all steps before starting.
Prepare the Commercial model
- Pause the unit, wait for the jets to stop, and unplug it.
- Facing the LED display, open the right-side vent.
- Close the skimmer ball valve by turning it perpendicular to the piping. Review the commercial skimmer details if needed.
- Keep the skimmer valve closed during the deep clean. Running the procedure with the skimmer open can pull air into the system and damage the unit.
Run the common procedure
Follow Deep Clean Any Plunge Cold Plunge. It requires one 16 fl oz bottle of Oh Yuk or a comparable cleaner at its labeled dose, water at 101°F to 104°F, at least eight hours of overnight circulation, and one 5-to-10-second filterless rinse only after draining and rinsing away the loosened buildup.
Return the Commercial model to service
- After the common procedure is complete, pause and unplug the unit.
- Install a clean filter and return the skimmer valve to its normal operating position according to the initial setup instructions.
- Refill and restart the unit.
- Add sanitizer according to the water maintenance manual. Do not combine sanitizer with line cleaner.
- Confirm normal flow.
If flow remains restricted or a CF error remains after one complete cycle, stop and contact Plunge Support.