If your sauna is turning off inadvertently after an hour, the problem you are encountering may have been caused by the newest firmware update featuring a revised algorithm designed to optimize the sauna experience.
The way it works:
- The first heating phase lasts 90 minutes, followed by a 10-minute break. After that, another 10-minute break happens, but the heater will reactivate if the temperature drops by more than 10°C during the break.
- The second heating phase lasts 45 minutes, followed by a 10-minute break. After that, another 5-minute break happens, but the heater will reactivate if the temperature drops by more than 10°C during the break.
- If the desired temperature is not achieved after this, the second phase will repeat. The cycle ends when the desired temperature is reached.
- If the heater is turned on, but the temperature in the sauna has not risen by 30°C in 60 minutes, the heater is turned off, as there must be something wrong – either the door is left open, or there is a window open, etc.
If you prefer to continue using the previous heating algorithm, please follow these steps within the user interface settings:
- Press and hold the button for about 10 seconds to access the settings.
- Select "Safety settings" from the menu.
- Choose "Failure det" and confirm the structural aspects of the sauna.
- Repeat the same confirmation process under the "Pauses" menu.
- Both settings will change to "Off," indicating the use of the old heating algorithm.