Keep a filter installed during all normal operation and troubleshooting. Identify whether you have a Standard or Pro chiller before starting.
1. Check the simple causes
- Fill the tub to the normal operating level.
- Confirm all operating valves are fully open.
- Confirm hoses are not kinked.
- Install a new, correctly seated filter.
- Clean the filter-housing O-ring and hand-tighten the lid.
2. Clean the hair strainer
Turn the chiller fully off and follow Cleaning the Hair Strainer on the Evolve Chiller.
3. Use the model-specific recovery
- Standard: complete the published Standard air purge up to three times.
- Pro: pause and restart once after installing a clean filter. If CF, no-flow, or fan protection returns, stop and contact Support.
Do not disconnect hoses, open a valve only briefly, open a powered compartment, or run without a filter. The only filterless exception is the 5-to-10-second rinse inside the complete overnight deep-clean procedure.
Still need help?
Submit a Plunge Support request. Include your product, serial number, and the results of the steps you completed.
Comments
0 comments
Please sign in to leave a comment.