Choose your chiller first: Standard or Pro. Both need clean filtered flow, open operating valves, ventilation, and a dedicated circuit — 15 amps for the Standard, 20 amps for the Pro.
1. Record the starting point
Write down the set temperature, displayed water temperature, ambient temperature, visible flow, and any error code. Allow 1 to 2 hours after a set-point change before treating the response as abnormal.
2. Check the filter and flow
- Install a clean, correctly seated filter.
- Confirm the O-ring and housing are clean and hand-tight.
- Confirm operating valves are fully open.
- Clean the hair strainer with the chiller fully off.
Standard: complete the Standard air purge.
Pro: restart the chiller using the published Pro restart. If CF or a no-flow code remains, contact Support after changing the filter.
3. Check installation conditions
- Use the model's manual for required ventilation clearance.
- Keep intake and exhaust areas clean and unobstructed.
- Shade the chiller when practical.
- Install the latest firmware on app-connected models.
Never disconnect hoses, manipulate valves while running, or remove the filter for an ordinary flow test.
Still need help?
Submit a Plunge Support request. Include your product, serial number, and the results of the steps you completed.